1. You are working as a plant electrician. It is your job to install a 300-hp three-phase squirrel-cage induction motor. The supply voltage is 480 V. The power company has determined that the maximum amount of starting current that can be permitted by any motor in the plant is 3000 A. The motor nameplate is as follows: Phase: 3 FLA: 352 Volts: 480 RPM: 1755 Frame: XXX Code: L Will it be possible to start this motor across the line, or will it be necessary to use a reduced-voltage starter to reduce starting current?

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
(Practical Application) #1 ) you are working as a plant electrician. It is your job to install a 300 hp three phase squirrel cage induction motor. The supply voltage is 480 V. The power company has determined that the maximum amount of starting current that can be permitted by any motor in the plant is 3000 A. The motor nameplate is as follows(photo) . Will it be possible to start this motor across the line, or will it be necessary to use a reduced voltage starter to reduce starting current?
PRACTICAL APPLICATIONS
1. You are working as a plant electrician. It is your job to install a 300-hp three-phase
squirrel-cage induction motor. The supply voltage is 480 V. The power company has
determined that the maximum amount of starting current that can be permitted by
any motor in the plant is 3000 A. The motor nameplate is as follows:
Phase: 3
FLA: 352
Volts: 480
RPM: 1755
Frame: XXX
Code: L m
Will it be possible to start this motor across the line, or will it be necessary to use a
reduced-voltage starter to reduce starting current?
Transcribed Image Text:PRACTICAL APPLICATIONS 1. You are working as a plant electrician. It is your job to install a 300-hp three-phase squirrel-cage induction motor. The supply voltage is 480 V. The power company has determined that the maximum amount of starting current that can be permitted by any motor in the plant is 3000 A. The motor nameplate is as follows: Phase: 3 FLA: 352 Volts: 480 RPM: 1755 Frame: XXX Code: L m Will it be possible to start this motor across the line, or will it be necessary to use a reduced-voltage starter to reduce starting current?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,